Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1948 1
1950 1
1955 1
1960 1
1963 1
1964 1
1965 4
1969 1
1970 1
1972 3
1973 1
1974 5
1975 13
1976 15
1977 15
1978 19
1979 13
1980 12
1981 14
1982 18
1983 16
1984 20
1985 20
1986 22
1987 43
1988 33
1989 63
1990 45
1991 54
1992 55
1993 60
1994 55
1995 68
1996 68
1997 81
1998 109
1999 119
2000 93
2001 106
2002 95
2003 106
2004 133
2005 111
2006 148
2007 140
2008 133
2009 166
2010 177
2011 150
2012 200
2013 179
2014 209
2015 194
2016 207
2017 199
2018 212
2019 228
2020 282
2021 309
2022 373
2023 396
2024 198

Text availability

Article attribute

Article type

Publication date

Search Results

5,372 results

Results by year

Filters applied: . Clear all
Page 1
X-ray Production.
Tafti D, Maani CV. Tafti D, et al. 2023 Jul 31. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. 2023 Jul 31. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. PMID: 30725731 Free Books & Documents.
The released electrons form in an electron cloud at the filament surface, and repulsion forces prevent the ejection of electrons from this negatively charged cloud. Upon application of a high voltage by an X-ray generator to the cathode as well as the anode, there is an …
The released electrons form in an electron cloud at the filament surface, and repulsion forces prevent the ejection of electrons from this n …
An electron counting algorithm improves imaging of proteins with low-acceleration-voltage cryo-electron microscope.
Zhu D, Shi H, Wu C, Zhang X. Zhu D, et al. Commun Biol. 2022 Apr 6;5(1):321. doi: 10.1038/s42003-022-03284-1. Commun Biol. 2022. PMID: 35388174 Free PMC article.
Relative to the 300-kV accelerating field, electrons accelerated under lower voltages are potentially scattered more strongly. Lowering the accelerate voltage has been suggested to enhance the signal-to-noise ratio (SNR) of cryo-electron microsc …
Relative to the 300-kV accelerating field, electrons accelerated under lower voltages are potentially scattered more st …
Voltage-dependent acceleration of Ca(v)1.2 channel current decay by (+)- and (-)-isradipine.
Berjukow S, Hering S. Berjukow S, et al. Br J Pharmacol. 2001 Aug;133(7):959-66. doi: 10.1038/sj.bjp.0704181. Br J Pharmacol. 2001. PMID: 11487504 Free PMC article.
(V1504A))=1.98 s) indicated that drug-induced determinants and determinants of intrinsic inactivation (V1504) stabilize the DHP-induced channel conformation in an additive manner. In the voltage range between -25 and 20 mV where the channels inactivate predominantly from t …
(V1504A))=1.98 s) indicated that drug-induced determinants and determinants of intrinsic inactivation (V1504) stabilize the DHP-induced chan …
Accelerating Electrochemical Reactions in a Voltage-Controlled Interfacial Microreactor.
Cheng H, Tang S, Yang T, Xu S, Yan X. Cheng H, et al. Angew Chem Int Ed Engl. 2020 Nov 2;59(45):19862-19867. doi: 10.1002/anie.202007736. Epub 2020 Sep 1. Angew Chem Int Ed Engl. 2020. PMID: 32725670
Microdroplet chemistry is attracting increasing attention for accelerated reactions at the solution-air interface. We report herein a voltage-controlled interfacial microreactor that enables acceleration of electrochemical reactions which are not observed in …
Microdroplet chemistry is attracting increasing attention for accelerated reactions at the solution-air interface. We report herein a …
Micrograph contrast in low-voltage SEM and cryo-SEM.
Liberman L, Kleinerman O, Davidovich I, Talmon Y. Liberman L, et al. Ultramicroscopy. 2020 Nov;218:113085. doi: 10.1016/j.ultramic.2020.113085. Epub 2020 Jul 30. Ultramicroscopy. 2020. PMID: 32771863
Modern high-resolution scanning electron microscopes (SEM), equipped with field emission guns (FEGs), designed to operate at low acceleration voltage, have opened new opportunities to study conductive or insulating systems, without conductive coating. ...We show how …
Modern high-resolution scanning electron microscopes (SEM), equipped with field emission guns (FEGs), designed to operate at low accelera
Excited state modulation of C(70) dimerization in a carbon nanotube under a variable electron acceleration voltage.
Liu D, Lungerich D, Nakamuro T, Harano K, Nakamura E. Liu D, et al. Micron. 2022 Sep;160:103316. doi: 10.1016/j.micron.2022.103316. Epub 2022 Jun 18. Micron. 2022. PMID: 35779330
To gain insight into the nature of the reactive species, we need to obtain kinetic information under various temperatures and variable acceleration voltages, i.e., electronic energy supply. We studied the mechanism of [2 + 2] dimerization of [70] fullerene in a carb …
To gain insight into the nature of the reactive species, we need to obtain kinetic information under various temperatures and variable ac
Causal theory on acceleration of seed germination in the vicinity of high voltage direct current transmission line.
Kumar A, Pandey OP. Kumar A, et al. J Theor Biol. 2021 Dec 21;531:110899. doi: 10.1016/j.jtbi.2021.110899. Epub 2021 Sep 9. J Theor Biol. 2021. PMID: 34509491
Although the literature supports the existence of seed germination acceleration, the lack of a definite causal theory has been observed by numerous researchers over decades. After considering all the existing experimental data, we have formulated a causal theory to explain …
Although the literature supports the existence of seed germination acceleration, the lack of a definite causal theory has been observ …
Influence of acceleration voltage on scanning electron microscopy of human blood platelets.
Pretorius E. Pretorius E. Microsc Res Tech. 2010 Mar;73(3):225-8. doi: 10.1002/jemt.20778. Microsc Res Tech. 2010. PMID: 20087904
Acceleration voltage allows electrons to penetrate the sample; thus, the higher the acceleration voltage the more penetration into the sample will occur. ...However, in biological sciences, this is an area that is not well-documented. Typically, acc
Acceleration voltage allows electrons to penetrate the sample; thus, the higher the acceleration voltage the mor
Effects of voltage on the emergence and spread of antibiotic resistance genes in microbial electrolysis cells: From mutation to horizontal gene transfer.
Zhang S, Sun WL, Song HL, Zhang T, Yin M, Wang Q, Zuo X. Zhang S, et al. Chemosphere. 2022 Mar;291(Pt 1):132703. doi: 10.1016/j.chemosphere.2021.132703. Epub 2021 Oct 27. Chemosphere. 2022. PMID: 34718024
However, little is known about the impacts of voltage on the acceleration of bacterial mutation and the promotion of ARG dissemination via horizontal transfer in MECs. ...The over-production of reactive oxygen species (ROS) (voltage >0.9 V) and cell membra …
However, little is known about the impacts of voltage on the acceleration of bacterial mutation and the promotion of ARG disse …
Acceleration of wound healing with high voltage, monophasic, pulsed current.
Kloth LC, Feedar JA. Kloth LC, et al. Phys Ther. 1988 Apr;68(4):503-8. doi: 10.1093/ptj/68.4.503. Phys Ther. 1988. PMID: 3258429 Clinical Trial.
The purpose of this study was to determine whether high voltage electrical stimulation accelerates the rate of healing of dermal ulcers. ...The ulcers of patients in the Control Group increased in area an average of 11.6% a week and increased 28.9% over a mean perio …
The purpose of this study was to determine whether high voltage electrical stimulation accelerates the rate of healing of derm …
5,372 results